Greetings,
One of our ESXi hosts crashed recently with Exception 14. The server is a Dell PowerEdge R520 with a PERC H710p RAID controller (originally it had a PERC H310, but we replaced it with the H710p and everything was running fine for about two months until the crash). The controller manages a RAID10 array of 4 SAS disks and a RAID0 array of 2 SSDs.
I have checked the forums and discovered that most probably the Expeption 14 PSOD is due to a hardware issue. Is there any indication on the attached screenshot of the PSOD that can point me to the right direction? What does the "megasas_reset_fusion" line mean? Do you think it's a faulty RAID controller?