Hi all,
I set up an UMDS and added the HP vibsdepot. I can see HP-patches in the patch store (E:\UMDS\hostupdate\HPQ).
But I can't see the hp-patches in the UM who is downloading from the UMDS.
What I noticed: the HPQ directory in not registered in the xml file in the hostupdate directory (__hostupdate20-consolidated-index__.xml).
Did I do anything wrong? Do I have to modify the xml file manually?
This is the current config:
c:\Program Files (x86)\VMware\Infrastructure\Update Manager>vmware-umds -G
[2013-08-08 11:56:22:891 '' 1780 ALERT] [logUtil, 265] Product = VMware UpdateManager, Version = 5.1.0, Build = 1022478
Configured URLs
URL Type Removable URL
HOST NO
HOST NO https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml
HOST NO https://hostupdate.vmware.com/software/VUM/PRODUCTION/csco-main/csco-depot-index.xml
HOST YES http://vibsdepot.hp.com/hpq/apr2013/index.xml
VA NO http://vapp-updates.vmware.com/vai-catalog/index.xml
Patch store location : E:\UMDS
Export store location :
Proxy Server : Not configured
Host patch content download: enabled
Host Versions for which patch content will be downloaded:
embeddedEsx-5.0.0-INTL
embeddedEsx-5.1.0-INTL
Virtual appliance content download: disabled
c:\Program Files (x86)\VMware\Infrastructure\Update Manager>