Hi ,
i have a host that crashes at least twice a day (ESXi 5) ,
the server is IBM 3850 , with 16 Go Ram
that is what i find in VMKWARNIG.LOG :
2013-04-01T14:39:35.600Z cpu13:2714)WARNING: iscsi_vmk: iscsivmk_StartConnection: Conn [CID: 0 L: 172.16.0.121:58313 R: 172.16.0.40:3260] TSC: 4855271224 cpu0:0)WARNING: SVGAConsole: 266: Extended TTY not supported. Ignoring on tty 0 TSC: 4855755600 cpu0:0)WARNING: SVGAConsole: 266: Extended TTY not supported. Ignoring on tty 2 TSC: 4856060720 cpu0:0)WARNING: SVGAConsole: 266: Extended TTY not supported. Ignoring on tty 3 TSC: 6312114056 cpu0:0)WARNING: HPET: 592: HPET counter runs at (12921597882%) of rated speed 0:00:00:04.106 cpu0:2048)WARNING: IOAPIC: 627: pin 16 is not masked 0:00:00:04.106 cpu0:2048)WARNING: IOAPIC: 627: pin 17 is not masked 0:00:00:04.107 cpu0:2048)WARNING: IOAPIC: 627: pin 16 is not masked 0:00:00:04.107 cpu0:2048)WARNING: IOAPIC: 627: pin 19 is not masked 0:00:00:04.107 cpu0:2048)WARNING: IOAPIC: 627: pin 20 is not masked 0:00:00:04.107 cpu0:2048)WARNING: IOAPIC: 605: ioapic 0, version 32 does not match ioapic0 version 17 0:00:00:04.110 cpu0:2048)WARNING: CacheSched: 801: Already disabled : Cache aware scheduling already disabled 0:00:00:04.126 cpu0:2048)WARNING: SVGAConsole: 266: Extended TTY not supported. Ignoring on tty 4 0:00:00:04.126 cpu0:2048)WARNING: SVGAConsole: 266: Extended TTY not supported. Ignoring on tty 5 2013-04-02T09:43:12.472Z cpu11:2658)WARNING: VMK_PCI: 1128: device 000:000:31.1 has no legacy interrupt(s) 2013-04-02T09:43:12.472Z cpu11:2658)WARNING: LinPCI: LinuxPCILegacyIntrVectorSet:80:Could not allocate legacy PCI interrupt for device 0000:00:1f.1 2013-04-02T09:43:12.699Z cpu2:2693)WARNING: LinuxSignal: 761: ignored unexpected signal flags 0x2 (sig 17) 2013-04-02T09:44:01.886Z cpu13:2658)WARNING: ScsiScan: 1485: Failed to add path vmhba1:C0:T0:L0 : Not found 2013-04-02T09:44:02.902Z cpu13:2658)WARNING: ScsiScan: 1485: Failed to add path vmhba1:C0:T1:L0 : Not found 2013-04-02T09:44:06.834Z cpu2:2705)WARNING: LinuxSignal: 761: ignored unexpected signal flags 0x2 (sig 17) 2013-04-02T09:44:11.957Z cpu13:2694)WARNING: UserObj: 3232: Unimplemented operation on 0x41000ffe5b60/RPC 2013-04-02T09:44:11.957Z cpu13:2694)WARNING: UserObj: 675: Failed to crossdup fd 9, cnxId: 0x80000000 type RPC: Not implemented 2013-04-02T09:44:17.690Z cpu15:2658)WARNING: APEI: 175: Could not initialize HEST 2013-04-02T09:44:19.520Z cpu13:2714)WARNING: iscsi_vmk: iscsivmk_StartConnection: vmhba33:CH:0 T:0 CN:0: iSCSI connection is being marked "ONLINE" 2013-04-02T09:44:19.520Z cpu13:2714)WARNING: iscsi_vmk: iscsivmk_StartConnection: Sess [ISID: 00023d000001 TARGET: iqn.1992-04.com.emc:storage.NAS-STORAGE.VNAS-DATASTORE TPGT: 1 TSIH: 0] 2013-04-02T09:44:19.520Z cpu13:2714)WARNING: iscsi_vmk: iscsivmk_StartConnection: Conn [CID: 0 L: 172.16.0.121:51719 R: 172.16.0.40:3260]
Can any body help me ??
PS: i've just added new memory bars , but i don't think it is the source of the problem.
Thanx in advance